Adelanto, CA
Unless otherwise noted, composite samples should be collected with the following frequency:
- 1 sample for 100 cubic yards or less
- 3 samples for 500 cu yds or less
- 5 samples for 1000 cu yds
- 1 additional sample for each additional 500cu yds greater than 1000 cu yd
Soil Safe – Adelanto TPST Sampling and Analysis Requirements for Sites Contaminated by Virgin Petroleum Products from Leaking Underground Storage Tanks:
- TPH (418.1 or 8015 modified)
- BTEX/VOC (8020 & 8010 or 8260)
Soil Safe – Adelanto TPST Sampling and Analysis Requirements for Sites Contaminated by Waste Oil or some other Non-Virgin Petroleum Product, or Virgin Petroleum Products from something other than a Leaking Underground Storage Tanks:
- Total Metals (TTLC test)
- TPH (418.1 or 8015 modified)
- BTEX/VOC (8020 & 8010 or 8260)
- PCB'S (Waste Oil Impacted Only)
- Additional analytical data as required